QXG specializes in customized substation transformers designed to meet diverse project specifications and application requirements — reliable, high-performance transformer solutions tailored to your power distribution needs.
QXG substation transformers feature a robust sealed tank design, providing reliable performance and protection under various operating conditions. With flexible customization capabilities, we tailor each transformer to meet specific project requirements, including special environmental conditions, installation altitudes, efficiency levels, voltage ratings, and structural configurations.
Designed to meet diverse international market requirements, QXG substation transformers can be manufactured in accordance with applicable standards such as ANSI, IEEE, CSA, IEC, and DOE. Supported by UL, cUL, and ISO certifications, we are committed to delivering dependable transformer solutions that meet customers' technical specifications and quality expectations.
With extensive experience in transformer manufacturing and a professional technical team, QXG provides flexible customization services to meet the specific requirements of different projects. From electrical specifications to structural configurations and component selection, we work closely with customers to develop transformer solutions tailored to their applications.
당사의 맞춤형 옵션은 다음과 같습니다.
If your project involves special technical requirements or non-standard configurations, please contact the QXG team. We will work with you to develop a suitable transformer solution.

QXG substation transformers are equipped with essential components and accessories designed to support safe operation, reliable performance, and convenient maintenance. Based on different project requirements, QXG offers a wide selection of transformer accessories and optional configurations, allowing customers to specify the components that best suit their electrical systems and installation conditions.
Monitors the insulating liquid level inside the transformer tank.
Indicates the transformer oil temperature during operation.
Releases excessive internal pressure to help protect the transformer tank.
Provides convenient access for filling or replenishing insulating oil.
Facilitates oil drainage and sampling for inspection and maintenance.
Allows voltage adjustment by changing winding taps when the transformer is de-energized.
Provide insulated electrical connections between the internal windings and external circuits.
Provide grounding connections for transformer safety.
Facilitate transportation, installation, and maintenance.
Displays essential transformer ratings, specifications, and identification information.


To accommodate different operating environments and project specifications, QXG can also provide:
QXG TECHNOLOGY is committed to delivering reliable and internationally compliant transformer solutions. Our products have successfully obtained UL certifications for both the U.S. and Canadian markets, demonstrating compliance with key industry standards including IEEE and CSA requirements. These certifications cover our substation transformers, supporting safe, reliable, and high-quality applications across utility, commercial, and industrial projects.





At QXG, we are committed to providing comprehensive support throughout every stage of your transformer project. With extensive experience in the electrical industry, professional technical expertise, and reliable supply chain resources, we work closely with customers to ensure efficient communication, smooth order execution, and dependable technical support.
Our professional sales and technical teams work closely with customers to understand their application requirements and project specifications. From product selection and technical consultation to customized solutions and quotations, we provide timely responses and practical recommendations to help you make informed purchasing decisions.
From order confirmation to production and shipment, QXG maintains close communication with customers throughout the manufacturing process. We coordinate production schedules, monitor quality control procedures, and provide timely updates on order progress. Before delivery, products undergo the required inspections and testing to ensure compliance with agreed technical specifications.
QXG continues to support customers after delivery through technical consultation, product documentation, and operational guidance. Our team assists with product-related inquiries, installation and commissioning guidance, and troubleshooting support when needed. We value long-term customer relationships throughout the product lifecycle.
At QXG, quality and reliability are integral to every stage of transformer manufacturing. Each substation transformer undergoes a series of factory inspections and routine tests before shipment to verify its electrical performance, insulation integrity, and operational reliability. Our testing procedures are conducted in accordance with applicable international standards, including ANSI, IEEE, CSA, and IEC, as well as specific customer and project requirements.
Verifies winding resistance and helps identify potential connection or manufacturing defects.
Confirms the transformation ratio, polarity, and vector group to ensure correct electrical connections.
Evaluates core performance and verifies no-load operating characteristics.
Checks transformer impedance and load losses to verify compliance with specified performance requirements.
Evaluates the insulation strength between windings and ground.
Verifies the insulation integrity between turns, layers, and other internal insulation components.
Assesses the condition of the transformer insulation system.
Checks tank integrity and verifies that the transformer is properly sealed against oil leakage.
Checks the operation and installation of tap changers, protective devices, gauges, valves, and other accessories.
Depending on transformer design, applicable standards, and project specifications, QXG can arrange additional tests, including:
Evaluates insulation performance against lightning overvoltage.
Verifies the thermal performance of the transformer under specified operating conditions.
Measures transformer noise levels to ensure compliance with specified acoustic requirements.
Evaluates insulation quality by detecting localized electrical discharges.
Assess the dielectric strength and other relevant properties of the insulating liquid.
| 전력 정격 | HV | LV | 폭 (mm) | 길이 (mm) | 높이 (㎜) |
|---|---|---|---|---|---|
| 315kVA | 11000V | 400V | 760 | 820 | 1340 |
| 500kVA | 27600V | 480GrdY/277V | 1755 | 2280 | 1525 |
| 500kVA | 11000V 델타 | 415V 스타 | 1720 | 1750 | 1680 |
| 750kVA | 11000V | 433V | 1870 | 1830 | 1490 |
| 1000kVA | 14400V | 415 / 240V | 1120 | 1880 | 1585 |
| 1200kVA | 13800V | 240V | 2420 | 1875 | 1800 |
| 1500kVA | 24940V | 600V | 1825 | 1860 | 1910 |
| 2000kVA | 7200V | 600GrdY/346 | 1790 | 2655 | 1965 |
| 2000kVA | 44000V | 600V | 1290 | 2110 | 1720 |
| 2500kVA | 24940V | 480GrdY/277V | 2380 | 2240 | 2080 |
| 3000kVA | 11000V | 415V | 1630 | 2350 | 1940 |
| 3000kVA | 22800V | 415 / 240V | 2100 | 3480 | 1935 |
| 3750kVA | 44000V | 600V | 2265 | 2620 | 2680 |
| 4000kVA | 33kV × 13.2kV | 600 년 / 347 년 | 2180 | 3220 | 2310 |
| 5000kVA | 34500V | 7200V | 3740 | 1885 | 3420 |
| 5000kVA | 34500V | 4160V 스타 | 2830 | 2380 | 2910 |
| 6300kVA | 35000V | 400V | 3490 | 2860 | 3450 |
| 6800kVA | 34500V | 800V | 3430 | 2690 | 3380 |
| 7500kVA | 27600Y | 델타 4160 | 3370 | 3270 | 2300 |
| 1500 / 2000kVA | 13800V | 480GrdY/277V | 1935 | 1780 | 2185 |
| 2500 / 3000kVA | 34500V | 480GrdY/277V | 2220 | 2680 | 2140 |
| 2500 / 3000kVA | 34500V | 480V | 2070 | 2650 | 2080 |
| 2500 / 3125kVA | 16500V | 600V 스타 | 2270 | 2000 | 2265 |
| 3000 / 4000kVA | 25000V | 600V | 2280 | 2880 | 2000 |
| 4000 / 5333kVA | 25000V | 600V | 2290 | 2920 | 2220 |
| 1.5MVA | 11000 / 6600V | 1000V 스타 | 1820 | 2180 | 1985 |
| 2.5MVA | 22000V | 11000V 스타 | 2820 | 2230 | 2120 |
| 3/4 MVA | 4160V | 480/277V Star | 2830 | 2120 | 2100 |
| 4/5 MVA | 13800V | 4160V 델타 | 3270 | 2740 | 2130 |
| 5/6.667 MVA | 44000V | 12470V | 2260 | 2210 | 3470 |
| 7.5/9.375 MVA | 34500V | 4160V | 2830 | 3760 | 3030 |
| 2000/2240–2500/2800 kVA | 13800V | 2 × 480/277V | 1980 | 2150 | 2390 |
QXG understands the importance of proper packaging in protecting substation transformers during transportation, particularly for long-distance overseas shipments. We use export-grade wooden packaging solutions to help protect transformers against potential impacts, moisture, and handling risks throughout the delivery process.
1. Wooden Crate Packaging: Reliable Protection — For shipments requiring enhanced protection, QXG can use heavy-duty wooden crates to secure the transformer during transportation. The packaging is designed to provide structural support and reduce the risk of damage caused by external impacts and handling. Appropriate protective materials are also used to help minimize moisture exposure during transit.
2. Export Wooden Pallet Packaging: Efficient Handling — For suitable transformer configurations, fumigated export wooden pallets can be used to support and secure the equipment. This packaging method facilitates handling, loading, and unloading while helping maintain stability during transportation.
At QXG, packaging arrangements are considered according to transformer dimensions, weight, transportation distance, and shipping requirements. Our goal is to ensure that each unit is properly protected and arrives at its destination in good condition, ready for installation.




QXG substation transformers are designed for a wide range of power generation, transmission, distribution, and industrial applications. With flexible voltage configurations, reliable performance, and customized designs, our transformers provide dependable power solutions for utility networks, renewable energy projects, energy storage systems, and data centers.
QXG substation transformers are essential components in utility substations and power distribution networks. They facilitate voltage transformation between transmission and distribution systems, support efficient power delivery, and help maintain grid stability. Flexible configurations are available to meet different utility project requirements.

QXG substation transformers provide reliable voltage transformation and grid connection for solar and wind power projects. They help integrate renewable energy into the electrical grid while supporting stable power transmission and efficient energy distribution.
View Case: 6250 kVA Substation TransformerQXG substation transformers enable efficient voltage conversion between battery energy storage systems (BESS) and the power grid. They support charging and discharging operations, facilitate grid integration, and help maintain stable power delivery and reliable system performance.

QXG substation transformers provide dependable power distribution for data centers, AI computing facilities, and mining operations. They support reliable voltage conversion and continuous power supply for high-demand electrical equipment, helping maintain operational stability and power system efficiency.
View Case: South America's Mining Industry
일반적으로 표준 변압기의 경우 4~8주 이내에 생산을 완료할 수 있으며, 배송 기간을 포함하여 이상적인 납기는 12주입니다. 실제 납기는 주문의 복잡성, 수량, 그리고 수령인의 위치에 따라 달라집니다.
QXG Technology는 10년 이상 패드 장착 변압기, 기둥 장착 변압기, 변전소 변압기 및 기타 유형의 변압기에 주력해 왔습니다.
네, 해외 브랜드 액세서리도 제공합니다. 부싱에는 주로 샤르동(CHARDON)과 쿠퍼(COOPER)를 사용하고, 퓨즈에는 주로 이튼(EATON)을 사용합니다. 게이지 및 기타 액세서리는 QUALITROL, EATON, HJ 등 중국 국내 및 해외 브랜드를 모두 제공합니다.
우리는 IEEE/ANSI/DOE/CSA 및 기타 북미와 라틴 아메리카 관련 표준을 엄격히 준수합니다.
저희는 특히 북미 시장에서 제품의 안전성과 품질을 입증하는 UL 및 CUL 인증을 보유하고 있습니다. 또한 CE, ISO 및 기타 신뢰할 수 있는 인증도 보유하고 있습니다.
네, 저희는 전문적인 OEM 서비스를 제공합니다. 독창적인 디자인 컨셉이든 특정 성능 요구 사항이든, 저희 팀은 고객과 협력할 준비가 되어 있습니다. 고객님의 사양에 맞춰 변압기를 제작해 드리며, 외관, 성능 매개변수, 포장까지 맞춤 제작해 드립니다.
모든 변압기에 2년 보증을 제공합니다. 이 기간 동안 제품 품질 및 설치 관련 문제가 발생할 경우, 저희 팀은 검사 및 수리에 적극 협조하고 온라인 및 오프라인 설치 서비스를 제공합니다.