2500 kVA Pad-Mounted Step-Up Transformer for Canadian Industrial Park

Project Overview

For a Canadian industrial park, QXG customized two units of 2500 kVA pad-mounted step-up transformers. The equipment adopts 12470 V delta high-voltage input and 480Y/277 V wye low-voltage output with Dyn1 vector group, equipped with dual cooling systems of ONAN (Oil Natural Air Natural) and ONAF (Oil Natural Air Forced). It provides round-the-clock stable grid interconnection power supply for the park’s natural gas CHP (Combined Heat and Power) units, large production workshops, energy storage grid-connected equipment and auxiliary machine rooms.

Northern Canada features harsh climate conditions, with temperatures ranging from as low as -40°C in winter to over 40°C in summer, creating an extremely wide annual temperature difference. The park’s gas generators represent typical non-linear loads with frequent harmonic surges during operation, and the transformers run at full load for long durations with prominent peak loads during unit startup and shutdown.

Project Challenges

  1. Operation under ultra-wide temperature outdoor conditions The transformers are installed on concrete pads in open air. The -40°C frigid winter imposes stringent requirements on the low-temperature resistance of sealing gaskets, insulating oil, secondary monitoring instruments and cabinet heating systems. Conventional seals and electronic components tend to fail and leak oil under low temperatures.
  2. High load bearing requirements Gas generators generate heavy harmonic currents with drastic instantaneous peak load fluctuations. The transformers are required to operate stably at rated 2500 kVA under ONAN cooling, and support short-time overload capacity up to 3333 kVA when cooling fans activate. Targeted optimization is mandatory for tap changer, heat dissipation and winding structures.

2500 kVA Pad-Mounted Transformer

Customized Solutions & Technical Advantages

  1. Dual North American Standard Compliance for Local Grid Interconnection & Insurance Approval The transformers are fully manufactured in accordance with CSA (Canadian Standards Association) standards, passing CSA factory inspection and affixed with official certification labels for legal installation and commissioning in Canada. The delta-connected high-voltage winding effectively suppresses 3rd harmonics produced by gas generators. The 600Y/347 V wye low-voltage side is fitted with an independent X0 neutral bushing to serve both three-phase power equipment and single-phase lighting loads. A 5-position DETC (De-Energized Tap Changer) is installed on the high-voltage side with a wide ±5% regulation range to counteract seasonal grid voltage variations.
  1. Full-temperature-range sealing design suitable for frigid Canadian outdoor environments Ultra-low-temperature resistant sealing gaskets are adopted for the tank cover, all inspection hatches and oil valves, paired with fully welded radiators. The tank is filled with Type II inhibited insulating oil, and the headspace is sealed with nitrogen to isolate air and moisture, eliminating winter condensation, oil oxidation and leakage risks. Core grounding is led out via a dedicated side-mounted bushing with an outdoor weatherproof hinged protective enclosure, ensuring leak-free tanks and stable insulation performance across all temperature ranges.
  1. ONAN & ONAF dual cooling system to withstand instantaneous unit peak loads The equipment operates maintenance-free via natural oil-air convection under basic load conditions, equipped with a complete cooling fan assembly. The outdoor control cabinet features Hand/Off/Auto three-position fan selector switches. Winding and oil temperature probes are embedded in dry wells, with temperature signals interlocked to automatically start and stop cooling fans. The transformer can run stably at full load under 2500 kVA ONAN rating, and the overload capacity rises to 3333 kVA once fans are activated, easily absorbing instantaneous surges from generator startup and shutdown to avoid excessive temperature rise and unexpected tripping.
  1. Complete Qualitrol monitoring & protection suite for unattended park operation Each transformer is fully fitted with original Qualitrol monitoring components, including non-contact pressure-vacuum gauge with Schrader nitrogen charging port, pressure relief device with alarm contacts, sudden pressure rise relay with lock-in function, liquid level gauge, winding temperature indicator and top oil temperature gauge. All alarm cables are routed uniformly to the outdoor sealed control cabinet. The cabinet is equipped with door-activated interior lighting and a thermostatically controlled dehumidifying heater to prevent condensation and secondary circuit corrosion in cold winter. All alarm signals can be interfaced with the park’s remote monitoring system for early fault warning.

 

Project Outcomes

The two 2500 kVA pad-mounted step-up transformers were delivered to the Canadian industrial park on schedule. After long-term outdoor operation at temperatures as low as -30°C in winter, the units show zero oil leakage, with fans, monitoring instruments and cabinet heating systems functioning reliably. Its harmonic suppression, temperature control and short-time overload performance all exceed contractual technical indicators, winning high recognition from both the park owner and local power utility.

QXG possesses mature customized manufacturing capacity for large-capacity pad-mounted transformers, delivering integrated packaged solutions for on-site power supply projects in Canadian industrial parks. Our products adapt to complex outdoor climates ranging from extreme cold to high temperature, while meeting industrial fire insurance and Canadian local grid interconnection codes simultaneously. We provide one-stop services covering drawing design, with extensive practical experience in distribution transformer project implementation across Canada.